Facing Reduction Coefficient μ
The coefficient μ accounts for the interaction between the slope facing and the nail heads when determining the total bearing capacity of nail. Its value ranges from 0 to 1 and depends on the facing type, structural arrangement and contact conditions with the ground.
- μ = 0: the contribution of the facing is neglected.
- 0 < μ < 1: the contribution of the facing is partially taken into account.
- μ = 1: the nail head resistance is considered without reduction by μ
A higher value of μ allows a greater contribution of the facing to load transfer.
Indicative Values of the Coefficient μ
μ | Typ krytu |
0,0 | Vegetation cover, erosion control mats |
0,2–0,6 | Shotcrete facing |
0,4–0,7 | Wire-rope-connected facing systems |
0,7–1,0 | Wire-rope-connected facing systems |
0,7–1,0 | Individual bearing plates |
0,7–1,0 | Concrete grid frame facing |
1,0 | Continuous rigid concrete facing |
Note: The selection of μ must also account for nail spacing and length, ground properties and the design guidance for the selected system. The coefficient μ does not replace verification of the facing and nail head resistance.
Sources:
NEXCO: Guidelines for the Design and Construction of Soil Nailing, January 2007, p. 50 (basic categories).
Daisho Co., Ltd.: Recommended Facing Reduction Factor (μ), technical document for GEO5 (additional values for wire-rope systems, high-tensile wire mesh and individual bearing plates).